AllergyIntolerance resource (FHIR R4)
AllergyIntolerance is a FHIR R4 resource. The Pidgeon engine generates synthetic AllergyIntolerance instances and validates them against the R4 structure definitions.
| Resource | AllergyIntolerance |
|---|---|
| FHIR version | R4 (4.0.1) |
| Canonical URL | http://hl7.org/fhir/StructureDefinition/AllergyIntolerance |
| Required elements | patient (1..1) |
| IG profiles in this catalog | 1 |
Example
{
"resourceType": "AllergyIntolerance",
"id": "allergyintolerance-e861a590e6a5fc8392ea6898ed0a6a0d",
"clinicalStatus": {
"coding": [
{
"system": "http://terminology.hl7.org/CodeSystem/allergyintolerance-clinical",
"code": "active",
"display": "Active"
}
]
},
"verificationStatus": {
"coding": [
{
"system": "http://terminology.hl7.org/CodeSystem/allergyintolerance-verification",
"code": "confirmed",
"display": "Confirmed"
}
]
},
"type": "allergy",
"category": [
"medication"
],
"criticality": "unable-to-assess",
"code": {
"coding": [
{
"system": "http://www.nlm.nih.gov/research/umls/rxnorm",
"code": "omitted",
"display": "RxNorm code omitted from this published example"
}
],
"text": "Sulfa drugs"
},
"patient": {
"reference": "Patient/patient-L46A6EIB9J"
},
"recordedDate": "2023-10-07",
"reaction": [
{
"substance": {
"coding": [
{
"system": "http://snomed.info/sct",
"code": "omitted",
"display": "SNOMED CT code omitted from this published example"
}
]
},
"manifestation": [
{
"coding": [
{
"system": "http://snomed.info/sct",
"code": "omitted",
"display": "SNOMED CT code omitted from this published example"
}
]
...Generated by the Pidgeon engine: pidgeon generate AllergyIntolerance --seed 20260722. Codes from licensed terminologies (LOINC, SNOMED CT, CPT, RxNorm) are omitted from published examples. Truncated for display; the command reproduces the full resource.
Validation context
- strict pidgeon validate grades a AllergyIntolerance instance against the base R4 structure definition: missing required elements raise REQUIRED_FIELD_MISSING and cardinality violations raise CARDINALITY_MIN or CARDINALITY_MAX.(REQUIRED_FIELD_MISSING)
- strict Profile validation grades the same instance against an installed IG profile: profile cardinality findings carry FHIR-PROFILE-CARDINALITY and terminology binding findings carry FHIR-PROFILE-BINDING.(FHIR-PROFILE-CARDINALITY)
This answer, in your terminal
pidgeon lookup AllergyIntoleranceWire it into your AI agent:
claude mcp add pidgeon -- npx -y @pidgeonhealth/mcpDownload Post free to browse this reference with generation attached.